The Biohazard Economic Line is ideal for most medical centers that need hospital grade medical waste treatment without large costly autoclaves. Designed to be economical high performance hard working autoclaves that offer substantial loading capacity and mobility in one easy to connect device.
Chamber volume of 160 liters
Features
- Advanced control system with touch pad control
- Chamber volume of 160 liters with minimal foot-print
- High volume water-ring vacuum-pump for fast and efficient air removal
- Stand-by heating mode keeps the autoclave warm and ready for use
- 316L grade stainless steel chamber and door with electro-polish finish
- Built-in alpha-numeric printer
- Mounted on wheels for easy mobility and sterilization on demand
- Pre-vacuum air stream sterilization
Safety Features
- Double locking safety device prevents door from opening at high pressure and high temperature
- Control lock-out switch prevents starting a cycle if door is not properly locked
Steam Supply
Saturated steam can be supplied to the autoclave from building.
Prevacuum Air Sterilization
All air that leaves the chamber prior to sterilization is treated as highly infectious and passes through a stringent biological decontamination system that renders the air sterile.
Thermal Sterilization
Prevacuum air leaves the chamber and makes contact with high temperature steam and is then passed through a high temperature heat exchanger which greatly increases the heat applied to the air making the air sterile and safe. The sterilized air is then cooled and any condensate is discharged to the drain.
Sterilization by Filtration
Prevacuum air is sterilized by passing it through a 0.2 μm biological filter. In order to maintain proper and effective filtration, the filter is sterilized in-place during every sterilization cycle.
Safe Landfill Disposal
- Sterilized medical waste which has been processed to remove sharps is simple to dispose in a municipal landfill
Environmentally Safe
- Chemical-free process
- No radiation
- Clean and environmentally safe technology
Cost-Effective
- Easy on-site installation removes need to transport waste to an external treatment facility
- Cost reduction in treatment and management of potentially infectious waste
- Reduced liability for waste producer due to no off-site treatment processing
- Relatively modest price and operating cost allows for quicker cost recovery
Strong Vacuum Pump
The built-in vacuum pump produces a strong vacuum that ensures proper air removal for excellent sterilization results.
Inactivation of Micro-organisms
After sterilization the number of micro-organisms are reduced to less than 10-6.
Fast Cooling for Fast Cycles
Fast cycles are an important factor that influences the waste processing time. A built-in cooling coil is an important feature that reduces cycle cooling times enabling higher cycle rates and empowering you to sterilize medical waste without delays.
Flexible PT100 for Liquid Loads
When treating blood, urine and other liquid medical waste a flexible PT100 placed in liquid waste load ensures sterilization at an effective sterilization temperature.
Specialized Loading Cart for Waste Transfer
A specialized loading cart for safely transferring medical waste is available with the following important features:
- The bottom shelf has no holes to prevent liquid from leaking out of the cart
- The bottom shelf has a drain to enable collection of any liquid waste into a container
- All the shelves have a barrier around their perimeter to prevent waste from falling off the cart